Fix Gun connection supervisor logic error
This was recently changed to solve a Dialyzer error, but the replacement logic was faulty as "retry" would only be compared to :error and not have its truthiness evaluated. The original logic was also faulty as it returned {:error, :pool_full} even retry was true. It never retried when the pool was full.
This commit is contained in:
parent
72480e7b2f
commit
0eca3e38eb
|
@ -0,0 +1 @@
|
||||||
|
Fix logic error in Gun connection pooling which prevented retries even when the worker was launched with retry = true
|
|
@ -21,7 +21,9 @@ def init(_opts) do
|
||||||
def start_worker(opts, retry \\ false) do
|
def start_worker(opts, retry \\ false) do
|
||||||
case DynamicSupervisor.start_child(__MODULE__, {Pleroma.Gun.ConnectionPool.Worker, opts}) do
|
case DynamicSupervisor.start_child(__MODULE__, {Pleroma.Gun.ConnectionPool.Worker, opts}) do
|
||||||
{:error, :max_children} ->
|
{:error, :max_children} ->
|
||||||
if Enum.any?([retry, free_pool()], &match?(&1, :error)) do
|
funs = [fn -> !retry end, fn -> match?(:error, free_pool()) end]
|
||||||
|
|
||||||
|
if Enum.any?(funs, fn fun -> fun.() end) do
|
||||||
:telemetry.execute([:pleroma, :connection_pool, :provision_failure], %{opts: opts})
|
:telemetry.execute([:pleroma, :connection_pool, :provision_failure], %{opts: opts})
|
||||||
{:error, :pool_full}
|
{:error, :pool_full}
|
||||||
else
|
else
|
||||||
|
|
Loading…
Reference in New Issue